CCLXB - OMC HI-VIS GEAR LUBE

  • MSDS: CCLXB
  • Manufacturer: CITGO PETROLEUM CORP
  • Product Name: OMC HI-VIS GEAR LUBE
  • National Stock Number: 9150-01-091-7500
Product Identification

Product ID:OMC HI-VIS GEAR LUBE
MSDS Date:05/08/1989
FSC:9150
NIIN:01-091-7500
MSDS Number: CCLXB

Responsible Party
CITGO PETROLEUM CORPORATION
TULSA, OK 74102
US

Emergency Phone: 318-491-6215;800-424-9300(CHEMTREC)

Info Phone: 918-495-5933

Cage: 7X110

Contractor
CITGO PETROLEUM CORP
3758 TULSA, OK 74102 US

Telephone: 918-495-5933

Cage: 7X110

Ingredients

REFINED PETROLEUM OIL(S) MIXTURE CONSISTING OF INGREDIENTS

RTECS: 9999999ZZ

Fraction By Weight: 97-99%


MINERAL OIL, PETRO DISTIL, SOLVENT-REFINED HEAVY PARAFFINIC

CAS: 64741-88-4

RTECS: PY8040500

OSHA PEL 5 MG/M3 (OIL MIST)

ACGIH TLV: 5 MG/M3 (OIL MIST)


REFINED PETROLEUM OIL

CAS: 64742-01-4


EXTREME PRESSURE, OXIDATION AND RUST INHIBITOR (MIXTURE).

Fraction By Weight: 1-4%


VI IMPROVER

Fraction By Weight: <0.1%

Hazards

LD50 LC50 Mixture:TLV 5 MG/M3 FOR OIL MIST
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION OF HIGH CONCENTRATIONS MAY
CAUSE DROWSINESS, DIZZINESS, HEADACHE, NAUSEA, LUNG IRRITATION. MAY
CAUSE CHEMICAL PNEUMONITIS. EYE CONTACT MAY BE MILDLY IRRITATING.
INGESTION OF LARGE AMOUNTS M AY CAUSE GENERALIZED DEPRESSION; SMALL
AMOUNTS MAY CAUSE IRRITATION AND DIARRHEA. CHONIC: SKIN DERMATITIS,
FOLLICULITIS.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO INGREDIENTS AT
CONCENTRATIONS OF 0.1% OR GREATER THAT ARE CARCINOGENS OR SUSPECT
CARCINOGENS.
Effects of Overexposure:DROWSINESS, DIZZINESS, HEADACHE, NAUSEA, LUNG
IRRITATION, CHEMICAL PNEUMONITIS, EYE IRRITATION, NAUSEA, VOMITING,
DIARRHEA, ERYTHEMA, EDEMA, SKIN DRYING/CRACKING, DERMATITIS,
FOLLICULITIS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: FLUSH WITH WATER FOR 15 MINUTES WHILE HOLDING EYELIDS
OPEN. GET MEDICAL ATTENTION. SKIN: REMOVE CONTAMINATED CLOTHING.
WASH WITH SOAP AND WATER. IF IRRITATION PERSIST, GET MEDICAL
ATTENTION. INH ALATION: REMOVE TO FRESH AIR. RESTORE BREATHING. GET
MEDICAL ATTENTION. INGESTION: DO NOT INDUCE VOMITING. GET MEDICAL
ATTENTION. SUBCUTANEOUS INJECTION IS MEDICAL EMERGENCY. SEEK
MEDICAL AID ASAP.

Fire Fighting

Flash Point Method:COC
Flash Point:460F,238C
Lower Limits:NOT GIVEN
Upper Limits:NOT GIVEN
Extinguishing Media:CO2, DRY CHEMICAL, FOAM, WATER FOG
Fire Fighting Procedures:FIRE FIGHTERS SHOULD WEAR SELF CONTAINED
BREATHING APPARATUS AND FULL PROTECTIVE GEAR. COOL TANKS AND
CONTAINERS EXPOSED TO FIRE WITH WATER.
Unusual Fire/Explosion Hazard:WATER MAY CAUSE FROTHING.

Accidental Release

Spill Release Procedures:REMOVE SOURCES OF HEAT, IGNITION. PROVIDE
ADEQUATE VENTILATION. CONTAIN LEAK. ABSORB WITH SUITABLE MATERIAL
SUCH AS RAGS, STRAW, SAND. REPORT SPILLS AS REQUIRED TO APPROPRIATE
AUTHORITIES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE BELOW 150F. DO NOT APPLY HIGH
HEAT OR FLAME TO CONTAINER. KEEP SEPARATE FROM STRONG OXIDIZING
AGENTS.
Other Precautions:EMPTY CONTAINERS RETAIN RESIDUE AND CAN BE DANGEROUS.
DO NOT PRESSURIZE, CUT, WELD, BRAZE, SOLDER, DRILL, GRIND OR EXPOSE
SUCH CONTAINERS TO HEAT, FLAME, SPARKS, STATIC ELECTRICITY OR OTHER
SOURCES OF IGNITION. THEY MAY EXPLODE.

Exposure Controls

Respiratory Protection:NORMALLY NONE REQUIRED. IF HIGH VAPOR OR MIST
CONCENTRATIONS EXPECTED, USE RESPIRATOR APPROVED BY NIOSH/MSHA FOR
ORGANIC VAPORS AND MISTS.
Ventilation:USE IN WELL VENTED AREA. CONFINED SPACE: MECH VENT MAY BE
REQD TO KEEP LEVELS OF CERTAIN COMPONENTS BELOW MANDATED STDS.
Protective Gloves:OIL IMPERVIOUS.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:WEAR BODY-COVERING WORK CLOTHES TO AVOID
PROLONGED OR REPEATED EXPOSURE.
Work Hygienic Practices:WASH EXPOSED SKIN THOROUGHLY WITH SOAP AND
WATER. REMOVE AND LAUNDER SOILED WORK CLOTHES BEFORE REUSE.
Supplemental Safety and Health
NOTE TO PHYSICIAN: CAREFUL GASTRIC LAVAGE WITH TIGHT FITTING OR CUFFED
TUBE IS PREFERRED OVER EMESIS. ASPIRATION MAY CAUSE CHEMICAL
PNEUMONITIS OR LIPOID PNEUMONIA. SUBCUTANCOUS INJECTION REQUIRES
PRO MPT SURGICAL DEBRIDEMENT.

Chemical Properties

HCC:V6
Boiling Pt:B.P. Text:750F,399C
Melt/Freeze Pt:M.P/F.P Text:NOT GIVEN
Decomp Temp:Decomp Text:NOT GIVEN
Vapor Pres:<3 X 10E-4
Vapor Density:>1
Spec Gravity:0.89
Evaporation Rate & Reference:<1 (BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:AMBER LIQUID, SLIGHT SULFURIZED ODOR.
Percent Volatiles by Volume:NEGLIG

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:THERMAL: CO2 (CO UNDER INCOMPLETE
COMBUSTION).

Disposal

Waste Disposal Methods:PREVENT WASTE FROM CONTAMINATING SURROUNDING
ENVIRONMENT. DISCARD ANY PRODUCT, RESIDUE, DISPOSAL CONTAINER OR
LINER IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.